Csb-battery EVX12260 User Manual

Browse online or download User Manual for Power suppliers Csb-battery EVX12260. CSB Battery EVX12260 User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Cells Per Unit 6
Voltage Per Unit 12
Capacity 26Ah @ 20hr-rate to 1.75V per cell @25
(77 )
Weight Approx 8.65 kg (19.07lbs)
Maximum Discharge Current 350A(5sec)
Internal Resistance Approx. 11.5 m
Operating Temperature Range
Nominal Operating Temperature Range 25
3 (77 5 )
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
(77 )
Recommended Maximum Charging 7.8A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
(77 )
Self Discharge CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal L terminal:B1/B3/B3B or Recessed type to accept M5 bolt
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
EVX 12260
12V 26Ah
Specification
Powered by
EVX 12260 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
125±1.5 (4.92±0.06) 122±1.5 (4.80±0.06)
166±2 (6.54±0.08) 175±2 (6.89±0.08)
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
27.3 16.5 11.8 9.54 7.03 5.66 4.68 3.18 2.63 1.44
1.67V
26.5 16.0 11.4 9.22 6.82 5.49 4.56 3.09 2.56 1.41
1.70V
25.7 15.5 11.1 8.97 6.59 5.32 4.43 3.00 2.48 1.37
1.75V
24.9 15.0 10.8 8.68 6.39 5.16 4.30 2.91 2.40 1.33
1.80V
24.1 14.6 10.4 8.41 6.19 5.00 4.16 2.81 2.32 1.28
1.85V
23.3 14.1 10.1 8.13 5.99 4.84 4.03 2.72 2.24 1.24
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
328 198 141 114 84.3 67.9 56.2 38.2 31.5 17.3
1.67V
318 192 137 111 81.4 65.7 54.6 37.2 30.6 16.9
1.70V
308 186 133 107 79.1 63.8 53.2 36.0 29.7 16.4
1.75V
299 181 129 104 76.7 61.9 51.6 34.9 28.8 15.9
1.80V
289 175 125 101 74.3 60.0 49.9 33.7 27.8 15.4
1.85V
280 170 121 97.1 71.9 58.1 48.3 32.6 26.9 14.9
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1403
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Drawing of recessed terminal
M5