Page view 0
Cells Per Unit 6
Voltage Per Unit 12
Capacity 34 Ah @ 20hr-rate to 1.75V per cell @25°C (77°F)
Weight Approx. 10.48 kg(23.06 lbs)
Maximum Discharge Current 380A(5sec)
Internal Resistance Approx. 8 mΩ
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging 10.2A
Current Limit
Equalization and Cycle Service
Self Discharge CSB Batteries can be stored for more than 6 months at
25°C
(77°F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal B5-L terminal to accept M6 nut & bolt
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge:
Charge:
Storage:
Constant Power Discharge Characteristics Unit:W (25°C,77°F)
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
GP 12340
12V 34Ah
Specification
Powered by
GP 12340 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
178.3±2 (7.02±0.08) 154.8±2 (6.09±0.08) 195.6±2 (7.7±0.08) 130±1.5 (5.12±0.06)
13.5 to 13.8 VDC/unit Average at 25°C(77°F)
14.4 to 15.0 VDC/unit Average at 25°C(77°F)
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
144 91.7 69.3 42.1 25.0 18.2 14.5 10.3 6.55 4.26 3.48 1.86
1.67V
128 85.5 65.5 41.3 24.7 18.0 14.4 10.2 6.50 4.23 3.43 1.78
1.70V
121 82.8 63.8 40.8 24.5 17.9 14.3 10.1 6.49 4.23 3.41 1.75
1.75V
110 77.5 61.2 40.0 24.4 17.8 14.2 10.0 6.47 4.18 3.35 1.69
1.80V
98.0 72.3 58.8 39.2 24.0 17.6 14.1 9.9 6.45 4.14 3.30 1.64
1.85V
86.3 67.0 55.7 38.2 23.6 17.4 14.0 9.8 6.43 4.09 3.24 1.58
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
1732 1100 832 505 300 218 174 124 78.6 51.1 41.7 21.6
1.67V
1539 1026 788 495 297 216 173 123 78.1 50.8 41.1 20.7
1.70V
1456 994 771 490 295 215 172 122 77.9 50.7 40.9 20.3
1.75V
1316 931 739 481 292 213 171 121 77.7 50.2 40.3 19.6
1.80V
1176 867 705 470 288 212 170 120 77.4 49.6 39.6 18.9
1.85V
1036 804 669 458 283 209 169 119 77.2 49.1 39.0 18.2
-15°C~50°C ( 5°F~122°F)
-15°C~40°C ( 5°F~104°F)
-15°C~40°C ( 5°F~104°F)
25°C±3°C (77°F±5°F)
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.