Page view 0
Cells Per Unit 3
Voltage Per Unit 6
Capacity 12A h @ 20hr-rate to 1.75V per cell
Weight Approx. 1.85 kg(4.08 lbs)
Maximum Discharge Current 150A/180A(5sec)
Internal Resistance Approx. 8.5 mΩ
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage 6.75 to 6.9 VDC/unit Average at
Recommended Maximum Charging 3.6A
Current Limit
Equalization and Cycle Service 7.2 to 7.5 VDC/unit Average at
Self Discharge CSB Batteries can be stored for more than 6 months at
Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal F1/F2-Faston Tab187/250
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge:
Charge:
Storage:
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
GP 6120
6V 12Ah
Specification
Powered by
GP 6120 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable , highly
efficient , leak proof and maintenance free.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
100±1 (3.94±0.04) 94±1 (3.7±0.04) 151±2 (5.94±0.08) 50±1 (1.97±0.04)
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
51.2 33.2 23.9 13.9 8.14 5.90 4.69 3.37 2.24 1.45 1.19 0.62
1.67V
48.2 32.0 23.6 13.7 8.12 5.84 4.62 3.35 2.21 1.44 1.18 0.61
1.70V
46.3 31.6 23.3 13.6 8.08 5.82 4.61 3.32 2.18 1.43 1.17 0.61
1.75V
43.3 30.0 22.6 13.4 8.03 5.77 4.57 3.26 2.13 1.40 1.15 0.61
1.80V
38.8 28.0 21.5 13.0 7.81 5.64 4.48 3.17 2.06 1.37 1.14 0.59
1.85V
34.2 25.3 19.8 12.3 7.51 5.41 4.29 3.03 1.97 1.32 1.09 0.57
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V
269 173 134 79.8 48.9 35.3 28.0 19.8 12.7 8.36 6.91 3.85
1.67V
257 171 132 79.6 48.8 35.1 27.8 19.7 12.6 8.30 6.85 3.81
1.70V
250 168 131 78.8 48.5 35.0 27.7 19.5 12.5 8.25 6.80 3.80
1.75V
231 163 128 78.1 48.1 34.6 27.5 19.3 12.2 8.12 6.69 3.77
1.80V
209 153 121 76.3 47.4 34.0 26.8 18.9 12.0 7.91 6.52 3.71
1.85V
185 140 111 72.2 45.8 33.1 26.3 18.1 11.7 7.73 6.36 3.61
Constant Power Discharge Characteristics Unit:W (25°C,77°F)
@25°C (77°F)
25°C (77°F)
25°C (77°F)
25°C (77°F).
-15°C~50°C ( 5°F~122°F)
-15°C~40°C ( 5°F~104°F)
-15°C~40°C ( 5°F~104°F)
25°C±3°C (77°F±5°F)
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Page view 0