Polypropylene(UL 94-HB) & Flammability resistance
of (UL 94-V0) can be available upon request.
XHRL12620W is specially designed for high efficient
discharge and long life application. Its characteristics are
high energy density, small footprint and high discharge
efficiency. It can be used for more than 260 cycles at 100%
discharge in cycle service, up to10 years in standby service.
Cells per unit
Voltage per unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Volt ag e
Recommended Maximum Charging
Current Limit
Equalization an d Cy cl e Service
Self Discharge
Terminal
Container Material
6
12
620W @15 min-rate to 1.67V per cell @25
(77 )
Approx. 47.2 kg (104.06 lbs)
800A(5sec)
Approx. 3.7 m
25 3 (77 5 )
13.5 to 13.8 VDC/unit Average at 25
(77 )
62 A
14.4 to 15.0 VDC/unit Average at 25
(77 )
CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
I2-Thread lead alloy recessed terminal to accept M6/M8 bolt
Discharge: -20 ~50 (-4 ~122 )
Charge: -20 ~50
(-4 ~122 )
Storage: -15
~40 (5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
XHRL12620W
12V 620W
Specification
Powered by
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
275.7±2.5 (10.85±0.10) 273.2±2.5 (10.76±0.10) 343.0±2.5 (13.50±0.10) 170.0±2.0 (6.69±0.08)
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
766 641 571 504 458 349 283 206 116 81.7
1.67V
660 585 511 466 420 326 273 200 114 79.8
1.70V
622 545 486 448 398 315 267 196 113 78.3
1.75V
553 485 449 398 356 293 252 188 110 78.2
1.80V
494 443 383 344 315 270 229 175 106 75.6
1.85V
437 360 322 298 280 239 201 158 97.9 71.1
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
7,070 6,088 5,529 5,280 4,692 3,770 3,108 2,304 1,344 966
1.67V
6,439 5,680 5,432 4,894 4,387 3,720 2,983 2,249 1,329 959
1.70V
6,090 5,494 5,336 4,692 4,262 3,540 2,918 2,222 1,325 957
1.75V
5,579 5,208 4,825 4,311 3,969 3,282 2,742 2,135 1,293 944
1.80V
5,235 4,660 4,246 3,894 3,639 2,956 2,515 2,017 1,247 916
1.85V
4,134 3,765 3,674 3,470 3,120 2,576 2,257 1,864 1,163 867
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
The system of manufacturer was certified
by TUV CERT according to ISO 9001,ISO 14001.
RA1310
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Page view 0
1 2

Summary of Contents

Page 1 - XHRL12620W

Polypropylene(UL 94-HB) & Flammability resistanceof (UL 94-V0) can be available upon request.XHRL12620W is specially designed for high efficient

Page 2 - XHRL 12620

68Charging ProceduresCharge Voltage(V/Cell)ApplicationTemperature Set Point Allowable RangeMax.Charge CurrentCycle Use25(77 )2.45 2.40~2.50Standby25 (

Comments to this Manuals

No comments