Csb-battery EVH12240 User Manual

Browse online or download User Manual for Power suppliers Csb-battery EVH12240. CSB Battery EVH12240 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Cells Per Unit 6
Voltage Per Unit 12
Capacity 24Ah @ 20hr-rate to 1.75V per cell @25
(77 )
Weight Approx. 7.55 kg (16.64 lbs)
Maximum Discharge Current 320A(5sec)
Internal Resistance Approx. 9 m
Operating Temperature Range
Nominal Operating Temperature Range 25
3 (77 5 )
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
(77 )
Recommended Maximum Charging 7.2A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
(77 )
Self Discharge CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal I1-Thread lead alloy recessed terminal to accept M5 bolt
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
EVH 12240
12V 24Ah
Specification
Powered by
EVH 12240 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
178.8±2 (7.04±0.08) 176±2 (6.93±0.08) 181±2 (7.13±0.08) 76.2±1 (3.0±0.04)
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
29.9 17.7 13.0 10.3 7.50 5.84 4.84 3.16 2.57 1.31
1.67V
29.6 17.5 12.9 10.2 7.44 5.83 4.78 3.15 2.56 1.30
1.70V
29.4 17.4 12.8 10.1 7.41 5.82 4.77 3.14 2.55 1.29
1.75V
29.0 17.2 12.7 10.0 7.32 5.74 4.73 3.09 2.52 1.28
1.80V
28.4 17.0 12.5 9.98 7.16 5.65 4.64 3.06 2.49 1.27
1.85V
27.0 16.2 11.9 9.56 6.85 5.44 4.47 2.91 2.34 1.17
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
346 208 154 123 88.9 69.9 58.6 38.3 31.4 16.2
1.67V
343 207 153 122 88.7 69.8 57.6 38.1 31.2 16.1
1.70V
340 206 152 121 87.9 69.1 57.4 38.0 31.0 16.0
1.75V
338 205 151 120 87.3 68.4 56.9 37.8 30.7 15.9
1.80V
331 199 147 118 85.1 67.1 55.9 37.2 30.3 15.7
1.85V
313 193 142 115 82.9 65.3 54.4 36.1 29.6 15.4
(http://www.csb-battery.com)
by URS according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Page view 0
1 2

Summary of Contents

Page 1 - EVH 12240

Cells Per Unit 6Voltage Per Unit 12Capacity 24Ah @ 20hr-rate to 1.75V per cell @25(77 )Weight Approx. 7.55 kg (16.64 lbs)Maximum Discharge Current 320

Page 2 - EVH12240

68 Charge Voltage(V/Cell) Application Temperature Set Point Allowable Range Max.Charge Current Cycle Use 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.

Comments to this Manuals

No comments