Cells Per Unit 6
Voltage Per Unit 12
Capacity 27W @ 15min-rate to 1.67V per cell @25
(77 )
Weight Approx.
1.97 kg(4.34 lbs)
Maximum Discharge Current 100/130A(5sec)
Internal Resistance Approx. 19 m
Operating Temperature Range
Nominal Operating Temperature Range 25
3 (77 5 )
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
(77 )
Recommended Maximum Charging 2.7A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
(77 )
Self Discharge CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
HR 1227W
12V 27W
Specification
Powered by
HR 1227W is specially designed for high efficient
discharge application. Its characteristics are high energy
density, small footprint and high discharge efficiency. It can
be used for more than 260 cycles at 100% discharge in cycle
service, up to 5 years in standby service.
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
106.0±1.5 (4.17±0.06) 101.8±1.5 (4.01±0.06) 90.0±1.0 (3.54±0.04) 70.0±1.0 (2.76±0.04)
F1/F2-Faston Tab187/250
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
55.4 36.5 27.5 22.1 18.7 13.6 10.9 7.88 4.55 3.23
1.67V
50.4 34.3 26.5 21.4 18.3 13.5 10.8 7.83 4.49 3.18
1.70V
45.6 32.2 25.3 20.8 17.8 13.1 10.7 7.77 4.47 3.16
1.75V
41.0 29.9 24.2 20.0 17.2 12.8 10.6 7.68 4.43 3.13
1.80V
36.4 27.5 22.7 18.9 16.3 12.4 10.3 7.49 4.35 3.08
1.85V
31.7 24.8 20.7 17.4 15.2 11.7 9.59 7.11 4.16 2.96
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
503 383 305 254 219 163 127 92.4 52.4 37.4
1.67V
469 358 288 242 211 162 126 91.6 52.3 37.3
1.70V
455 347 280 236 206 161 125 91.3 52.2 37.1
1.75V
428 327 268 229 200 158 124 90.3 51.8 36.8
1.80V
403 309 255 218 192 153 120 88.2 51.3 36.7
1.85V
377 290 240 208 184 144 114 84.4 49.2 35.1
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
(http://www.csb-battery.com)
RA1308
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.